<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-15 20-41-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 67 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.0 kHz 84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19038 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 1,89 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"The Royal Philharmonic Orchestra, Lee Min (Viulu) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,0053 Acquired: 2024/10/15 20.40.21 Total samples: 19038 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,6 dBr MIN: 0,5 dBr AVE: 1,89 dBr % above 12,2 dBr: 0,0 Last value: 2,0 dBr (2024/10/15 20.40.20) 20.26 20.28 20.30 20.32 20.34 20.36 20.38 20.40 0 50 100 Dev. MAX [kHz] -1 0 1 2 3 4 Pm [dBr]